7:26A-3.19 Additional application requirements for generalapproval to operate a recycling center for the receipt,storage, processing or transfer of Class D recyclablematerials
(a) Prior to commencing receipt, storage, processing or transfer of used oil at a recycling center, the owner or operator of the recycling center shall submit to the Department, in addition to the information required pursuant to N.J.A.C. 7:26A-3.2, the following information:
1. The EPA ID number assigned to the facility;
2. A description of the preparedness and prevention procedures and equipment required by N.J.A.C. 7:26A-6.7(c)1;
3. A copy of the contingency plan as required by N.J.A.C. 7:26A-6.7(c) 2;
4. A description of the secondary containment system for containers or tanks to demonstrate compliance with N.J.A.C. 7:26A-6.7(e)4, 5 or 6, including at least the following:
i. Drawings and a description of the basic design parameters, dimensions and materials of construction of the containment system;
ii. The capacity of the containment system relative to the number and volume of containers or tanks within the system;
iii. A description of how the design promotes drainage or how the containers or tanks are protected from contact with standing liquids in the containment system;
iv. Provisions for preventing or managing accumulated precipitation or run-on; and
v. A description of how accumulated liquids will be analyzed and removed to prevent overflow;
5. A demonstration of compliance with labeling requirements of N.J.A.C. 7:26A-6.7(e)7;
6. A description of closure procedures and/or copy of the closure plan to demonstrate compliance with N.J.A.C. 7:26A-6.7(e)9;
7. A copy of an analysis plan as required by N.J.A.C. 7:26A-6.7(f);
8. A description of the method used to comply with the tracking requirements of N.J.A.C. 7:26A-6.7(g); and
9. A demonstration of compliance with the residue management requirements in accordance with N.J.A.C. 7:26A-6.7(j).
(b) Prior to commencing the receipt, storage, processing or transfer of any latex paints, antifreeze, lamps (light bulbs), oil-based paints, batteries, mercury-containing equipment and consumer electronics at a recycling center, the owner or operator of the recycling center shall submit to the Department, in addition to the information required pursuant to N.J.A.C. 7:26A-3.2, the following information:
1. The EPA ID number assigned to the facility;
2. A description of the preparedness and prevention procedures and equipment required by N.J.A.C. 7:26A-4.6(b);
3. A copy of the contingency plan as required by N.J.A.C. 7:26A-4.6(c);
4. A description of the secondary containment system for containers or tanks to demonstrate compliance with N.J.A.C. 7:26A-4.6(d)1iii or (d)2ii, including at least the following:
i. Drawings and a description of the basic design parameters, dimensions and materials of construction of the containment system;
ii. The capacity of the containment system relative to the number and volume of containers or tanks within the system;
iii. A description of how the design promotes drainage or how the containers or tanks are protected from contact with standing liquids in the containment system;
iv. Provisions for preventing or managing accumulated precipitation or run-on; and
v. A description of how accumulated liquids will be analyzed and removed to prevent overflow;
5. A description of the design and operation of process buildings to demonstrate compliance with N.J.A.C. 7:26A-4.6(d)3, if applicable. The description shall include at least the following:
i. Drawings and a description of the basic design parameters, dimensions and materials of construction of the process building;
ii. The design capacity of the building relative to the volume of recyclable materials to be stored or processed within the building; and
iii. A description of the liquid collection and removal system required by N.J.A.C. 7:26A-4.6(d)3iii (if applicable), including a discussion of how accumulated liquids will be characterized and removed;
6. A demonstration of compliance with labeling requirements of N.J.A.C. 7:26A-4.6(e); and
7. A description of closure procedures and/or copy of the closure plan to demonstrate compliance with N.J.A.C. 7:26A-4.6(g).
New Rule, R. 1996 d. 577, effective December 16, 1996. See: 28 N.J.R. 2240(a), 28 N.J.R. 5360(a). Administrative change. See: 30 N.J.R. 3948(a). Amended by R. 2002 d. 182, effective June 17, 2002 (operative December 17, 2002). See: 33 N.J.R. 4273(a), 34 N.J.R. 2088(a). In (a), substituted "Prior to commencing receipt" for "Prior to the receipt" preceding "storage," and substituted "used oil" for "any Class D recyclable materials" following "or transfer of in the introductory paragraph; added (b). Amended by R. 2009 d. 52, effective February 2, 2009. See: 40 N.J.R. 7(a), 41 N.J.R. 742(a). In the introductory paragraph of (b), deleted "thermostats," preceding "lamps" and substituted "equipment" for "devices".